OPERATION | ||
|
|
|
USER MEMORIES
Recall a memory with memory buttons
To recall a user a memory, press one of the six user memory buttons. The memory is recalled when the button is released. Do not hold the button for more than two seconds when recalling a user memory.
Recall a memory with the gun trigger
If desired, memories 2 through 6 can be recalled with the gun trigger. For example, to recall memory 3, quickly pull and release the gun trigger 3 times without welding.
Note: the Power Feed™ 10M Single Wire Feeder is factory set with this feature disabled. Use the SETUP menu and change P.4 to enable memory recall with the gun trigger.
Save a memory with memory buttons
To save a memory, press and hold the desired memo- ry button for two seconds. When the button is initially pressed, the corresponding LED will illuminate. After two seconds, the LED will turn off. Do not hold the button for more than 5 seconds when saving a user memory.
Note that memories may be locked in the Setup menu to prevent accidental overwrite of the memories. If an attempt is made to save a memory when memory sav- ing is locked, the message "Memory save is Disabled!" will appear briefly in the MSP4 display.
RECALL SAVE
PRESS 1 PRESS 2
SECOND SECONDS
6.OPTIONAL DUAL PROCEDURE/MEMORY PANEL OPERATION
The Dual Procedure/Memory Panel performs three functions:
•Weld procedure selection
•Memory save and recall
•Limits setting
There are two procedure memories (A and B) and six user memories
Procedure Memory vs. User Memory
Procedure memory is used while welding. Changes to the weld procedure (WFS, voltage, arc control, etc.) immediately change the contents inside the selected procedure memory. Procedure memory saving is done automatically.
User memories work by copying the weld procedure from one of the six memories into either the A or B procedure. Weld procedures are saved into the mem- ories only when the operator chooses.
USER
PROCEDUREMEMORIES
MEMORY
|
|
| M | MEMORY | M |
PROCEDURE |
|
|
| ||
A | GUN | B | 1 | 2 | 3 |
|
|
| |||
|
|
|
| HOLD 2 SECONDS TO SAVE |
|
|
|
| 4 | 5 | 6 |
| M | MEMORY | M |
PROCEDURE |
|
|
|
A GUN B | 1 | 2 | 3 |
|
HOLD 2 SECONDS TO SAVE
4 5 6
DIP SWITCH SETTINGS
“S9” Switch on
Dip Switch on P.C. board. (Single Head Feeder)
Using Procedure Memories
Procedure memories can be selected by choosing either "A" or "B" procedure directly with the memory panel, or by selecting "GUN" and using a dual proce- dure gun to select between procedure "A" and "B". When selecting procedures with the gun switch, "A" or "B" will flash to show which procedure is active.
| M | MEMORY | M |
PROCEDURE |
|
|
|
A GUN B | 1 | 2 | 3 |
| |||
|
| HOLD 2 SECONDS TO SAVE |
|
| 4 | 5 | 6 |
PRESS TO |
|
|
|
SELECT |
|
|
|
PROCEDURE |
|
|
|