TROUbLESHOOTING |
Observe all Safety Guidelines detailed throughout this manual
Error Codes for the Power Wave® 455: Code 10555 and below
Note: For any Err # listed below write down the error number for refference and try cycling power to see if the error clears itself. If not, refer to what the What to Do column for the given Err.
PRObLEMS
(SYMPTOMS)
POSSIbLE
CAUSE
RECOMMENDED
COURSE OF ACTION
| Display shows any of the following: |
|
|
|
|
|
|
|
|
|
|
|
|
| Err 211 |
| Microprocessor RAM error in |
| Turn Power off at power source. |
|
|
|
| Control Box. |
| Wait 5 seconds. Turn power back |
|
|
|
|
|
| on. If Err 211 is displayed again, |
|
|
|
|
|
| then replace CB mother PC board. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Err 212 |
|
| Microproceeor RAM Error in object |
| Cycle power as in Err 211. If Err |
|
|
|
| board other than Control Box (Such |
| 212 is still displayed, then replace |
|
|
|
| as feed head) |
| PC board in the object with fault. |
|
|
|
|
|
| The object with the fault should be |
|
|
|
|
|
| solid red on its status LED. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Appears on right display of CB mod- |
| Dashes indicate that the encoder |
|
|
|
| ule that contains the status Led |
| does not control anything including |
|
|
|
|
|
| on/off output control. |
|
|
|
|
|
|
|
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.