TROUbLESHOOTING

E-3

 

 

 

Observe all Safety Guidelines detailed throughout this manual Error Codes for the Power Wave 455: Code 10555 and below

Note: For any Err # listed below write down the error number for refference and try cycling power to see if the error clears itself. If not, refer to what the What to Do column for the given Err.

 

PRObLEMS

POSSIbLE

RECOMMENDED

 

(SYMPTOMS)

CAUSE

COURSE OF ACTION

 

 

 

 

 

 

 

 

Display shows any of the following:

 

 

 

 

 

 

 

 

 

 

 

 

 

Err 020

An attempt was made to reprogram

Check for potential electrical HF

 

 

 

 

a CB or feed head but the program

noise generators in the area. Try

 

 

 

 

did not verify.

removing the noise source and pro-

 

 

 

 

 

 

gramming again. If the Err 020 still

 

 

 

 

 

 

occurs, either replace the EEPROM

 

 

 

 

 

 

chop(s) in teh board being

 

 

 

 

 

 

reprogammed or replace the whole

 

 

 

 

 

 

PC board being reprogrammed.

 

 

 

 

 

 

 

 

 

Err 100

The Power Source issued a shut

 

See what to Do on Err 006.

 

 

 

 

down command for some reason.

 

 

 

 

 

 

 

 

 

 

 

Err 200

 

 

 

 

 

No Heart beat response from the

 

See what to Do on Err 006.

 

 

 

 

PS.

 

 

 

 

 

 

 

 

 

 

 

Err 201

No Heart beat response from an

 

If this occurs while welding, the sta-

 

 

 

 

object.

 

tus LED should be flashing red on

 

 

 

 

 

 

the object that lost heart beat.

 

 

 

 

 

 

Otherwise, look for any nodes that

 

 

 

 

 

 

are flashing green. This indicates

 

 

 

 

 

 

they have not been recognized and

 

 

 

 

 

 

there is a power source problem

 

 

 

 

 

 

(see power source trouble shooting

 

 

 

 

 

 

section). If the status LED is either

 

 

 

 

 

 

flashing or solid red, there may be a

 

 

 

 

 

 

problem with continuity in the com-

 

 

 

 

 

 

munication lines. Check the lines for

 

 

 

 

 

 

continuity, in the cable and harness-

 

 

 

 

 

 

ing (refer to wiring diagram).

 

 

 

 

 

 

 

 

Err 210

 

 

 

 

 

 

EEPROM error.

 

Parameter recaled at power up was

 

 

 

 

 

 

out of range. Rotate encoder knob

 

 

 

 

 

 

to reset . Check all settings before

 

 

 

 

 

 

procedding to weld. If this condition

 

 

 

 

 

 

persists the replac the CB mother

 

 

 

 

 

 

PC board.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.