E-8

TROUbLESHOOTING

E-8

 

 

 

 

Observe all Safety Guidelines detailed throughout this manual

 

 

 

 

PRObLEMS

(SYMPTOMS)

POSSIbLE

CAUSE

RECOMMENDED

COURSE OF ACTION

 

 

LINC-NET SYSTEM ERROR CODES

 

 

Err 006

 

1. The wire feeder has not received

 

 

 

 

a recognition command from the

 

 

 

 

power source. Verify the power

 

 

 

 

source is operating properly

 

 

 

 

(Status light steady green.)

 

 

 

2.

Check control cable for loose or

 

 

 

 

broken leads.

 

 

 

3.

See power source service

 

 

 

 

Manual.

 

 

 

 

Err 100

 

1. The power source has issued a

 

 

 

 

shutdown command. Verify the

 

 

 

 

power source is operating proper-

 

 

 

 

ly. (Status light steady green.)

 

 

 

2.

Check control cable for loose or

 

 

 

 

broken leads.

 

 

 

3.

See power source service

 

 

 

 

Manual.

 

 

 

 

 

 

ARCLINK SYSTEM

ERROR CODES

Err 31

 

Primary overcurrent

1. The power source has exceeded

 

 

 

 

input current limits. Adjust the

 

 

 

 

welding procedure to reduce the

 

 

 

 

current draw. The welding proce-

 

 

 

 

dure may exceed the capacity of

 

 

 

 

the power source.

 

 

 

2.

See the power source service

 

 

 

 

Manual.

 

 

 

 

Err 32

 

Capacitor bank "A" under

1. The power source input power

 

 

voltage.

 

may be wired incorrectly. Verify

 

 

 

 

the power source reconnect

 

 

 

 

panel wiring matches the input

 

 

 

 

power.

 

 

 

2. See the power source service

 

 

 

 

Manual.

 

 

 

 

 

 

 

 

 

 

Check to see if the STATUS LED on the Power Wave 455 is not steady green. If it is not steady green, refer to the Power Wave 455 Status LED Chart and Code Table. Check the control cables for loose or faulty con- nections. Also check the continuity of all five leads from one end to the other. The control board in the PW 455 may be faulty.

See Err 006 in this chart.

CAUTION