System Behavior in Response to Sensor Events

FRU State Management

 

 

A.5 FRU State Management

The following table provides the SAM action, FRU status, hot swap state for each FRU temperature sensor in the shelf.

Table A-1 FRU State Table for Nonrecoverable Threshold Events from Temperature Sensors

FRU

Temperature Sensor

SAM Action

 

FRU Status

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Hot Swap

 

 

 

Step-1

Step-2

Operation

State

H/S LED

 

 

 

 

 

 

 

Active

Sensor # 6("MAX6656 INT

Set all FAN-

 

H/S LED

M6->M1

Turn ON

SAM

@1A")

module speed

 

ON. Still

(Logical

 

 

Sensor # 7("MAX6656 EXT1

MAX

 

working as

SAM

 

 

@1A")

 

 

Active.

(0x20) will

 

 

Sensor # 8("MAX6656 EXT2

 

 

 

show M4

 

 

@1A")

 

 

 

state)

 

 

 

 

 

 

 

 

Standby

Sensor # 6("MAX6656 INT

Set all FAN-

 

H/S LED

M6->M1

Turn ON

SAM

@1A")

module speed

 

ON.

 

 

 

Sensor # 7("MAX6656 EXT1

MAX

 

 

 

 

 

@1A")

 

 

 

 

 

 

Sensor # 8("MAX6656 EXT2

 

 

 

 

 

 

@1A")

 

 

 

 

 

 

 

 

 

 

 

 

PEM

Sensor # 12 ("DS75 Temp")

Set all FAN-

Issue

Still working.

M6 > M1

Turn ON

 

 

module speed

"deactivate"

 

 

 

 

 

MAX

command to

 

 

 

 

 

 

PEM

 

 

 

 

 

 

 

 

 

 

ATCA-

Sensor # 8 ("Inlet Temp")

Set all FAN-

Issue

Payload

M6 > M1

Turn ON

F101

 

module speed

"deactivate"

powered

 

 

 

 

MAX

command to

down by the

 

 

 

 

 

F101

SAM.

 

 

 

 

 

 

 

 

 

 

Sensor # 9 ("Outlet Temp")

Set all FAN-

Issue

Payload

M6 > M1

Turn ON

 

 

module speed

"deactivate"

powered

 

 

 

 

MAX

command to

down by the

 

 

 

 

 

F101

SAM.

 

 

 

 

 

 

 

 

 

 

Sensor # 10 ("PMC Temp")

Set all FAN-

Issue

Payload

M6 > M1

Turn ON

 

 

module speed

"deactivate"

powered

 

 

 

 

MAX

command to

down by the

 

 

 

 

 

F101

SAM.

 

 

 

 

 

 

 

 

 

 

Sensor # 20 ("Artesyn Temp")

Set all FAN-

Issue

Payload

M6 > M1

Turn ON

 

 

module speed

"deactivate"

powered

 

 

 

 

MAX

command to

down by the

 

 

 

 

 

F101

SAM.

 

 

 

 

 

 

 

 

 