Airport Systems

All Flashheads stuck

in Day Mode

Are any LEDs

No

on Master

 

 

 

 

 

 

Controller lit?

 

 

 

 

Yes

 

 

 

 

 

 

 

Does MC

 

 

 

 

 

 

show Green

 

 

 

FH Status

Yes

LEDs?

 

 

 

 

No

 

 

 

 

 

 

 

Replace MC Fuse F1.

Does MC

Yes

show Green

 

PC OK LED

 

(DS28?)

 

No

 

 

 

 

 

 

Troubleshoot Flashheads Individually.

Check Photocell Wiring.

If wiring OK, replace Photocell.

Is Master

Controller No

COM OK LED

lit? (DS34)

Yes

No

Is Master

Yes

Controller

Unplug MC TB5

 

COM OK LED

 

 

lit? (DS34)

 

 

No

 

Check for shorts between communication cable and power wiring.

Is Comm

Cable wired to

MC TB5

correctly1?

 

Yes

 

Perform

No

Comm Wiring

 

Tests2. Is

 

wiring OK?

 

 

Yes

 

 

 

 

 

Visually examine MC for damage near TB5.

 

 

If damaged, replace Master Controller PC Board.

Correct wiring.

 

 

Otherwise, replace Master Controller chip U2.

 

 

 

Make sure only a single (a top-level) Flashhead has SW4-1 (TERM) set to on. Check for shorts or breaks in the communication cable.

Troubleshoot each Flashhead individually.

1Per Section 2.4.2

2Per Section 2.5.4 and page 4-2

Figure 4-1: General Troubleshooting – All Flashheads Stuck in Day Mode

SG-60 High Intensity Strobe System

4-3

Manual EPM-00000019 Rev A

Page 66
Image 66
Honeywell SG-60 installation and operation guide General Troubleshooting All Flashheads Stuck in Day Mode