Airport Systems

Red Lights don’t turn

on at night.

Is MC K4

No

wired to RLC

 

 

 

 

Photo Input?

 

 

 

Yes

 

 

 

 

 

Is MC TB6

 

No

wired to RLC

 

 

 

Top Beacon

 

 

Alarms?

 

 

Manually turn on

Red Lights at RLC.

1.Disconnect RLC Photocell.

2.Connect wiring from MC

Red/Night relay K4 to RLC Photocell Input.1

Connect wiring from MC TB-6 to Top Red Beacon alarms.2

Does MC Red

Yes

Check wiring from MC Red/Night

Ready LED light

up (DS36)?

No

relay K4 to RLC Photocell Input.1

Is RLC reporting

No

a Top Beacon

 

Alarm?

 

 

Yes

 

 

 

Repair Failed Top Beacon.

Check wiring from MC TB-6 to Top Red Beacon alarms.2

1Per Section 2.4.4.1

2Per Section 2.4.4.2

Figure 4-4: Dual System-Specific Troubleshooting

SG-60 High Intensity Strobe System

4-6

Manual EPM-00000019 Rev A

Page 69
Image 69
Honeywell SG-60 installation and operation guide Dual System-Specific Troubleshooting