Airport Systems

Flashhead stuck in

Day Mode

Is DB DS3

No

green LED

 

 

steady off?

 

 

Yes

 

 

 

Are Comm

No

wires correctly

 

wired in FH

 

TB1? 1

 

 

Yes

 

 

 

Are Comm

No

wires correctly

 

wired in MC

 

TB5? 2

 

 

Yes

 

 

 

 

 

 

Remove all power from FH and MC.

Perform Comm Wiring

tests (Installation Check3, and A-B Continuity Check. 4)

Will FH

operate in No other modes

with manual selection?

Yes

Correct wiring.

Correct wiring.

Did wires pass

No

isolation and

 

 

 

 

continuity

 

 

checks?

 

 

 

Yes

 

 

 

 

 

 

 

 

Replace Digital

 

 

Board.

 

 

 

 

 

 

Check if problem is resolved after each step taken.

1.Replace Digital Board.

2.Check for loose connections to coil of FH K2 Relay

3.Replace FH K2 relay.

Check for loose mounting nuts on FH switch assembly. Make sure FH Remote/Local interlock is pressed when door latched.

Locate and repair break.

1Per Section 2.4.2

2Per Section 2.4.5

3Per Section 2.5.4

4Per page 4-2

Figure 4-3: General Troubleshooting – Flashhead Stuck in Day Mode

SG-60 High Intensity Strobe System

4-5

Manual EPM-00000019 Rev A

Page 68
Image 68
Honeywell SG-60 installation and operation guide General Troubleshooting Flashhead Stuck in Day Mode