If your red light system has a Honeywell 9LCA Series Red Light Controller, locate the Alarm terminals and Flasher Bypass terminals corresponding to the top beacon, and make the following connections:

Master Controller TB6-1 -----------------

to ----------------------

9LCA Flasher Bypass C1

9LCA Flasher Bypass NC1 -------------

to ----------------------------

9LCA Alarm Card C1

Master Controller TB6-2 -----------------

to --------------------------

9LCA Alarm Card NC1

Note: Usually the top beacon terminals are found on the top/left Flasher Bypass Card (TB4), and the left channel of the top Alarm Card (TB3).

Other Red Light Systems may require different connections. Refer the to Tower Kit drawing (if both systems were provided as a kit by Honeywell), the Red Light System's manual, or contact Honeywell for assistance.

2.4.5Flashhead Wiring

Incoming AC power and data communications enter the Flashhead in a single cable, Honeywell P/N WC000001, that combines three wires for AC power with a twisted-pair/double-shielded data cable (See Figure 2-9, Page 2-21). Typically, Flashheads are supplied with a 10-20 foot length of this cable already installed.

Should you need to install or replace this cable, make the connections for incoming AC power and data to Flashhead TB1 per Figure 2-5, Page 2-11, and Figure 2-10, Page 2- 24, as follows.

Green wire (Equipment ground) ------------------------

to

----------------- Flashhead TB1-1

White wire (Phase or neutral) ---------------------------

to

----------------- Flashhead TB1-2

Black wire (Phase or hi) ----------------------------------

to

----------------- Flashhead TB1-3

Data Cable

 

 

White or Clear wire (Data signal "A") ------------

to

----------------- Flashhead TB1-4

Blue wire (Data signal "B") --------------------------

to

----------------- Flashhead TB1-5

Inner shield (Data shield)----------------------------

to

----------------- Flashhead TB1-6

Outer shield --------------------------------------------------------

trim short; not connected

2.4.6Conduit and Tower Wiring Detail

This section details a standard practice of installing conduit and the related tower lighting wires for the system. Please use this guide to help install the wires into the conduit system. The wires and cables for the SG-60 High Intensity system need to be run properly to insure that the system will work properly. Wire insulation that is damaged will lead to a system that will not function properly and may void the warranty. Insure that the following procedure is followed. Pay close attention to all bold text.

SG-60 High Intensity Strobe System

2-14

Manual EPM-00000019 Rev A

Page 29
Image 29