Page 73
Image 73

Airport Systems

5.Unpack the new flashtube. Do not touch the glass envelope - contamination from a fingerprint will degrade the reliability of the flashtube.

6.Holding the flashtube by its metal ends, center it in the reflector assembly and snap it into place. Make sure the red mark on the flashtube matches the red mark on the socket assembly.

7.Attach the faston connector at each end of the flashtube to each socket assembly. Make sure wires are not twisted - the metal to glass bond is fragile.

8.Refer to Figure 5-2 below. Dress the electrode wires away from the sides of the reflector.

9.Close and fasten the Flashhead cover.

Figure 5-2: Flashtube Installation

5.3Ambient Light Sensor (Photocell)

The only maintenance required for the photocell is periodic cleaning. The frequency of cleaning depends on the environment to which the photocell is exposed.

SG-60 High Intensity Strobe System

5-3

Manual EPM-00000019 Rev A

Page 73