Honeywell SG-60 If SW2-2 is set for an External RED system ON, then

Models: SG-60

1 81
Download 81 pages 30.74 Kb
Page 44
Image 44

Airport Systems

§DS32 - 33 – (Figure 2-10, Item 5, Page 2-25) The indications on these lights are dependent on the setting for external red light system on SW2.

If SW2-2 is set for an EXTERNAL RED system (ON), then

DS32 – ON indicates there has been a red light system alarm sometime during the night and the red light system is off, but will reset the next day. OFF when in night mode and the red light system is not in alarm

DS33 – ON indicates in night mode, red lights are turned off and white strobes are operating, OFF indicates NORMAL operation.

If SW2-2 is set for no EXTERNAL RED system (OFF) then

DS32 – ON during DAY and TWILIGHT, OFF during NIGHT mode

DS33 - Not used (lower right of board)

§DS31 – (Figure 2-10, Item 5, Page 2-25) ON indicates power OK, OFF indicates power failure

§DS30 – (Figure 2-10, Item 5, Page 2-25) ON indicates photocell is GOOD, OFF indicates photocell is BAD or not connected

§DS29 – (Figure 2-10, Item 5, Page 2-25) ON indicates all Flashheads are good, OFF indicates one or more Flashheads are bad

2.6.2Flashhead Status Indicators

Miscellaneous Indicators (Figure 2-11, Item 1, Page 2-26)

§ DS1 Red ON for 5-Volt logic power OK

§DS2 Yellow ON for Flash Current Feedback OK

§DS3 Green ON Steady for communications OK (receive & transmit) OFF for no communications reception

Slow Blink (1/sec) for receiving but not being addressed to transmit

Fast Blink (4/sec) for receiving, being addressed to transmit but failing to transmit

2.6.3System Power Up

All switches and indicators listed in this section are in the Master Controller, except for the external system circuit breakers.

1.Verify POWER SWITCH is turned OFF.

2.Verify LOCAL / REMOTE switch is set to LOCAL.

3.Verify MODE switch is set to DAY.

4.Turn on circuit breaker to apply power to Master Controller.

5.Turn on circuit breaker to apply power to Flashheads.

6.Turn POWER SWITCH to ON.

SG-60 High Intensity Strobe System

2-29

Manual EPM-00000019 Rev A

Page 44