Troubleshooting Checklist

Troubleshooting Checklist

If the module is not working properly, refer to Table 4‐2 for a checklist of problems, possible causes, and recommended actions to resolve the problem.

Table 4-2 Troubleshooting Checklist

Problem

Possible Cause

Recommended Action

 

 

 

All LEDs are OFF.

Loss of power.

Ensure that the module was installed properly

 

 

according to the installation instructions in

 

 

Chapter 3, and that the host chassis is providing

 

 

power.

 

 

 

No Local

Incorrect terminal setup.

Refer to the Matrix DFE-Gold Series Configuration

Management

 

Guide for proper setup procedures.

Password screen.

 

 

Improper console cable

Refer to Appendix A for proper COM port pinouts.

 

 

pinouts.

 

 

 

 

 

Corrupt firmware image,

If possible, attempt to download the image to the

 

or hardware fault.

module again. Refer to “Setting the Mode

 

 

Switches” on page B-2 for instructions to clear

 

 

NVRAM.

 

 

 

Cannot navigate

Improper username/

If the username/password combination has been

beyond Password

password combination

forgotten, refer to Refer to “Setting the Mode

screen.

entered.

Switches” on page B-2 for instructions on how to

 

 

set the mode switch to reset the username/

 

 

password combination to the default values.

Cannot contact the module through in-band management.

IP address not

Refer to the Matrix DFE-Gold Series Configuration

assigned.

Guide for the IP address assignment procedure.

 

 

Port is disabled.

Enable port. Refer to the Matrix DFE-Gold Series

 

Configuration Guide for instructions to enable/

 

disable ports.

 

 

Host Port policy and/or

Verify that a management VLAN exists and that it

management VLAN is

is associated with the Host Port.

incorrectly configured,

Refer to the Matrix DFE-Gold Series Configuration

or not configured.

Guide for information about Host Port and

 

 

management VLAN configuration.

 

 

No link to device.

Verify that all network connections between the

 

network management station and the module are

 

valid and operating.

 

If the problem continues, contact Enterasys

 

Networks for technical support.

Matrix DFE-Gold Series PoE Module 4H4285-49 Installation Guide 4-7

Page 63
Image 63
Enterasys Networks 6H308-48, 4H4285-49 manual Troubleshooting Checklist, Refer to the Matrix DFE-Gold Series Configuration