Enterasys Networks 9033989-06, 6H308-48, 4H4285-49 manual Rx/Tx

Models: 9033989-06 4H4285-49 6H308-48

1 90
Download 90 pages 12.31 Kb
Page 62
Image 62

Using LANVIEW

Table 4-1 LANVIEW LEDs (continued)

LED

Color

State

Recommended Action

 

 

RX/TX LED Indications in PoE Port Status Mode

 

 

 

 

 

RX/TX

Green/

There is a connection to a

None.

 

Off

PD. There is 48 Vdc at the

 

 

 

RJ45 connector.

 

Off/Red Port is off due to overload. The attached device exceeded maximum load according to 802.3af standard PoE device power classification.

1.Check the attached PD to see if it is defective and drawing too much power for its Power Classification.

2.Check Ethernet cable from the PD for short circuits.

3.Contact Enterasys Networks for technical support.

Red/Off Port is off due to PoE power None management. Port may be

turned off due to priority or other administration configuration.

Off/Off

Port is off for other reason.

1.There is no connection to a PD.

2.If the DFE module is in an N5 chassis, ensure that the N5 is turned on.

3.If connected to an N-POE Power System, ensure that the power system is turned on.

4.If the power is being received from an N-POE Power System, check the 48 Vdc power cable connection.

5.Swap 48 Vdc power cable with a known good one.

6.If you still have a problem, contact Enterasys Networks for technical support.

4-6 Troubleshooting

Page 62
Image 62
Enterasys Networks 9033989-06, 6H308-48, 4H4285-49 manual Rx/Tx