Troubleshooting Checklist

Table 4-2 Troubleshooting Checklist

(continued)

 

 

 

Problem

Possible Cause

Recommended Action

 

 

 

Port(s) goes into

Loop condition

Verify that Spanning Tree is enabled. Refer to the

standby for no

detected.

Matrix DFE-Gold Series Configuration Guide for

apparent reason.

 

the instructions to set the type of STA.

 

 

Review the network design and delete

 

 

unnecessary loops.

 

 

If the problem continues, contact Enterasys

 

 

Networks for technical support.

 

 

 

User parameters

Position of Mode switch

Reenter the lost parameters as necessary. Refer

(IP address, device

(7), Persistent Data

to the Matrix DFE-Gold Series Configuration

and module name,

Reset, was changed

Guide for the instructions to configure the device.

and so forth) were

sometime before either

If the problem continues, contact Enterasys

lost when the

cycling power or

Networks for technical support.

module power was

pressing the OFFLINE/

 

cycled, the front

RESET switch, causing

 

panel OFFLINE/

the user-entered

 

RESET switch was

parameters to reset to

 

pressed.

factory default settings.

 

Clear Persistent Data was set through Local Management.

The module was moved either from slot-to-slot or from chassis-to- chassis.

4-8 Troubleshooting

Page 64
Image 64
Enterasys Networks 4H4285-49, 6H308-48, 9033989-06 manual Matrix DFE-Gold Series Configuration Guide for