Setting the Mode Switches

Setting the Mode Switches

Caution: Read the appropriate sections to be fully aware of the consequences when changing switch settings.

Only qualified personnel should change switch settings.

Precaución: Si desea modificar la configuración del interruptor, lea las secciones correspondientes para saber cuál será el resultado de hacerlo.

Estas modificaciones a la configuración sólo debe realizarlas personal calificado.

Figure B‐1 shows the location of the mode switches and the switch settings for normal operation. These switches are set at the factory and rarely need to be changed.

Switch definitions and positions are as follows:

Switches 1 through 6 – For Enterasys Networks use only.

Switch 7 – Clear Persistent Data. Changing the position of this switch clears Persistent Data on the next power‐up of the module. All user‐entered parameters, such as the IP address, module names, and others, are reset to the factory default settings. Once the module resets, you can either use the factory default settings or reenter your own parameters.

Switch 8 – Clear Admin Password. Changing the position of this switch clears the admin password, and restores the factory default password on the next power‐up of the module. Once the module resets, you can either use the factory default settings or reenter your own password.

Note: Do not change the position of Switch 8 unless it is necessary to reset the admin password to its factory default setting.

B-2 Mode Switch Settings and Option Installations

Page 72
Image 72
Enterasys Networks 6H308-48, 4H4285-49, 9033989-06 manual Setting the Mode Switches