Gaining Access to Memory Modules
Matrix DFE-Gold Series PoE Module Hardware Installation Guide B-5
Removing the Safety Cover
RefertoFigureB3andproceedasfollows:
1. Attachtheantistaticwriststrap(refertotheinstructionsontheantistaticwriststrap
package).
2. PlacetheDFEGoldmodule onanantistaticpadonasturdyflatsurface.
3. Removethesevenscrewsfasteningthesafetycovertothesevenstandoffsonthemain
board.Saveallscrewsforlaterusetoreinstallthesafetycover.
4. IfyouarereplacingtheDRAMSIMM,proceedtoDRAMSIMMReplacement
ProcedureonpageB7.Ifyou needtoreplacetheDIMM,proceedtoDIMM
ReplacementProcedureonpageB10.
Warning: The safety cover protects you from exposure to an energy hazard in excess of
240 Volt-Amperes. Never operate the DFE module without the safety cover installed.
Advertencia: La cubierta de seguridad lo protege de exponerlo al riesgo de energía en
exceso de 240 Volt-Amperes. Nunca se debe opererar el modulo de DFE sin la cobertura
de seguridad instalada.
Warnhinweis: Die Sicherheitsabdeckung schützt vor Stromstössen von bis zu 240 VA.
Bitte nehmen Sie niemals die DFE Module ohne die Abdeckung in Betrieb.