Mounting the Switch

Placing the Switch on a Flat Surface

When installing the switch on a flat surface, the installation of the rubber feet is recommended to prevent the switch from sliding. Also, the surface must be able to support 15.5 kg (35 lbs) of static weight.

To install the rubber feet, proceed as follows:

1.Place the switch upside down on a sturdy flat surface.

2.Remove the four rubber feet from the shipping box.

3.Remove the protective strip from the back of one rubber foot and position it on one of the corners on the bottom of the switch. Press firmly into place. Repeat this procedure to install the remaining rubber feet in the other corners.

4.After installing the rubber feet, return the switch to its upright position.

5.Place the switch in its final location.

Installing the Switch into a Rack

Caution: Before installing the screws as described in this installation procedure, refer to “Torque Values” on page A-5.

Precaución: Antes de retirar los tornillos, tal como se describe en las instrucciones de instalación, consulte “Torque Values” on page A-5.

The G‐Series Ethernet switch can be mounted in a standard EIA‐310‐D compliant 48.26‐centimeter (19‐inch) equipment rack. To mount the switch into a rack, you must first install the rack‐mount kit, which consists of two brackets. You must provide the mounting hardware to attach the switch brackets to the rails.

Note: The G-Series Ethernet switch (with rubber feet installed) will exceed the 2U high Richmond standard and will not comply with the requirements for mounting in a 19-inch (48.26-centimeter) rack. Remove the rubber feet, if installed, before installing the switch into a rack.

To install the rack‐mount kit and then install the switch into the rack:

1.Place the switch on a sturdy flat surface.

2.Install one of the brackets provided in the rack‐mount kit to the side of the switch using the screws provided as shown in Figure 2‐1.

3.Repeat the previous steps to install the other bracket to the other side.

2-4 Installation

Page 26