Console Port Pinout Assignments

Table A-22 XFP Fiber-Optic Specifications

Module

Wavelength

Tx Power

Rx Sensitivity

Link Power

MTBF

Min/Max (avg.)

Min/Max (avg.)

Budget

(hours)

 

 

 

 

 

 

 

10GBASE-LR-XFP

1310 nm DFB

-8.2 / 0.5 dBm

-14.4

/ 0.5 dBm

9.4 dB

2,631,579

 

 

 

 

 

 

 

10GBASE-ER-XFP

1550 nm EML

-4.7 / 4.0 dBm

-15.8

/ -1.0 dBm

15 dB

2,000,000

 

 

 

 

 

 

10GBASE-ZR-XFP

1550 nm EML

0 / 4.0 dBm

-25 / -7.0 dBm

18 dB

1,164,047

 

 

 

 

 

 

10GBASE-SR-XFP

850 nm VCSEL

-7.3 / -1.0 dBm

-9.9 / -1.0 dBm

7.3 dB

4,081,633

 

 

 

 

 

 

 

The specifications listed in Table A‐23 meet or exceed the IEEE 802.3ae‐2002 standard.

Table A-23 Recommended Cable Types and Specifications

Item

Type

Max. Reach

Min. Reach1

Connector

10GBASE-LR-XFP

SMF (Single Mode Fiber)

10 km (6.21 mi)

2 m (6.6 ft)

LC

 

 

 

 

 

10GBASE-ER-XFP

SMF (Single Mode Fiber)

40 km (24.85 mi)2

2 m (6.6 ft) with

LC

 

 

 

minimum of 5 dB

 

 

 

 

attenuation

 

10GBASE-ZR-XFP SMF (Single Mode Fiber) 80 km (49.7 mi)

2 m (6.6 ft) with

LC

minimum of 11 dB

 

attenuation

 

10GBASE-SR-XFP MMF (Multimode Fiber)

300 m (984 ft)

2 m (6.6 ft)

LC

1.The limiting factor is saturation of the receiver by the transmitter. When presented with a signal at a strength above the saturation point, the receiver cannot distinguish between pulses, though no hardware damage occurs.

2.Links longer than 30 km for the same link power budget are considered engineered links. Attenuation for such links needs to be less than the minimum

Console Port Pinout Assignments

Refer back to Connecting to the RJ45 Console Port on page 2‐13 for console port pinout information.

Regulatory Compliance

The G3G124‐24, G3G124‐24P and G3G170‐24 meet the safety and electromagnetic compatibility (EMC) requirements listed in Table A‐24:

Table A-24 Compliance Standards

Regulatory Compliance

Standards

 

 

 

UL 60950, CSA C22.2 No. 60950, 2006/95/EC, EN 60950, and

 

IEC 60950. The Mini-GBICs that support laser connections also

Safety

meet the EN 60825 and 21 CFR 1040.10 standards.

 

 

 

47 CFR Parts 2 and 15, CSA C108.8, 2004/108/EC, EN 55022,

 

EN 61000-3-2, EN 61000-3-3, EN 55024,

Electromagnetic Compatibility (EMC)

AS/NZS CISPR 22, and VCCI V-3.

 

 

A-10 Specifications

Page 58
Image 58
Enterasys Networks G3G124-24P Console Port Pinout Assignments, Regulatory Compliance, Table A-24 Compliance Standards