Installing and Removing a Power Supply

Figure 2-2 Installing a Power Supply Module (1200-watt module into PWR 2 slot shown)

1 Power supply

2 Power supply handle

3 Captive screws

7.Secure the power supply to the chassis by tightening the captive screws.

8.If you are installing an additional power supply, repeat step 4 through step 7. If not, ensure that the unused power slot has a coverplate installed over it.

Refer to “Power Supply Planning” on page 2‐6 for information on configuring the switch’s power mode.

Removing a Power Supply

To remove a power supply, proceed as follows:

1.Attach an anti‐static wrist strap before handling the power supply module.

2.Unplug the associated power cord from the outlet.

3.Unplug the power cord from the AC inlet (associated with the power supply you are removing) at the back of the chassis.

4.Unscrew the captive screws to release the power supply from the chassis.

5.Remove the power supply by grasping the handle and pulling it straight out of the chassis.

6.Fasten a coverplate over the empty slot.

Caution: If you plan to operate the chassis with only one power supply, be sure to install the coverplate in place of the removed power supply to contain EMI radiation and ensure proper air circulation.

Precaución: Si desea trabajar sólo con una fuente de poder, no olvide colocar la tapa en el compartimiento de la fuente de poder que haya eliminado, para reducir la interferencia electromagnética y para asegurar una buena ventilación.

2-8 Installation

Page 30
Image 30
Enterasys Networks G3G170-24, G3G124-24P manual Removing a Power Supply, Power supply Power supply handle Captive screws