Adjustment4.1.1 Platen Gap Adjustment

This adjustment is performed to obtain the appropriate gap between the head nozzle surface and the platen. It must be adjusted after reinstalling or replacing the CR guide shaft, CR unit or parallelism adjust bushing. The specified value range for the platen gap is 1.26 ± 0.02 mm.

1.Set the right and left parallelism adjust bushings to the middle of the adjusting range.

2.Place the thickness gauges at the illustrated positions in Figure 4-1.

Thickness Gauge

Figure 4-1. Thickness Gauge Placement

3.(See the flowchart in Page 4-3.)

Turn the left parallelism adjust bushing to make the gap as follows: Wide enough to insert a 1.24 mm-thick gauge

Too narrow to insert a 1.28 mm-thick gauge

(Table 4-2 shows the direction for moving the parallelism adjust bushing to make the platen gap from wide to narrow or vice versa.)

Table 4-2. Direction for turning the Parallelism Adjust Bushing

Platen gap

Left parallelism adjust

Right parallelism adjust

 

bushing

bushing

 

 

 

 

 

 

To narrow

Clockwise

Counterclockwise

 

 

 

To widen

Counterclockwise

Clockwise

 

 

 

4. Apply the same procedure for the right parallelism adjust bushing.

CAUTION

￿Be sure to place the thickness gauge under the both black and color printheads.

￿Before moving the CR unit, set the PG adjust lever to “+” to open the platen gap.

4-2

Rev. A