EPSON Stylus COLOR 3000

3.2.6 Printer Mechanism Unit Removal

1.Remove the upper housing. (See Section 3.2.1)

2.Disconnect the following connector cables from the connectors on the main board assembly:

CN3

CN4

CN 5

CN6

CN7

CN10

CN11 CN12

CN13

CN14

CN18

CN20

CN21

CN22

CN23

3.Disconnect the ASF PW sensor connector cable from the PW sensor connector on the left edge guide of the ASF assembly.

4.Remove 7 screws (6 CB screws, 4X14 and 1 CBP screw, 3X8) securing the printer mechanism unit to the lower housing.

CAUTION

The connectors for the motor (CN20,22 and 23) and for the ink cartridges (CN7, 12, 13 and

14)look similar. Therefore, be sure to connect them properly, since inappropriate connection may result in malfunction of the PSE/PSB board or the main control board.

WORK POINT

￿Be sure to lubricate the top surface of the paper eject frame in an ASP printer mechanism unit, since the frame, along which the CR unit slides, is not lubricated.

￿After installing the printer mechanism unit to the lower housing, be sure to insert the waste ink draining tubes linking to the pump unit into the sub waste ink drain pads. (See Section 3.2.11.7.)

REQUIRED ADJUSTMENT

￿After replacing the printer mechanism unit, perform required adjustments to write appropriate values such as head data and several adjustment values into the EEPROM on the main control board. (See Chapter 4.)

CB Screws (4X14)

Printer Mechanism Unit

CB Screws (4X14)

 

 

Paper Eject Frame

 

 

ASF PW Sensor

 

 

ASF PW Sensor

 

CBP Screw (3X8)

 

 

Connector Cable

 

 

Lower Housing

Figure 3-8. Printer Mechanism Unit Removal

Rev. A

3-11