EPSON Stylus COLOR 3000

3.2.9 Main Waste Ink Drain Pad Removal

Note) In case the value for the protect counter A* has reached the limit and the maintenance error is indicated, or the value has exceeded 60,000, replace the waste ink drain pads on the agreement with your customer.

*: The value for the protect counter A can be found on the sheet printed during the default setting mode.

(Refer to Chapter 1, Section 1.5.2.1.)

1.Perform EEPROM reset. (See Section 1.5.1 in Chapter 1.)

2.Remove upper housing. (See section 3.2.1.)

3.Remove the printer mechanism unit. (See Section 3.2.6.)

4.Remove the main waste ink drain pads. (See Section 3.2.9.)

WORK POINT

Current value for the protect counter A is shown along with the ROM version number on the test print sheet (1st line on the top page) printed in the default setting mode. (See Section 1.5.2.)

Cartridge Holder Unit

Waste Ink Drain Pad

Lower Housing

Figure 3-11. Main Waste Ink Drain Pad Removal

Rev. A

3-15