Adjustment
4.1.9 Sensor CheckThis operation is performed to store several values in the EEPROM. The values and the sensors used are as follows:
Value used as the basis for the detecting paper quantity remaining in ASF. PQ sensor attached to the right edge guide in ASF is used.
Value used as the basis for the detecting paper width and the following sensors are used:.
ASF PW (Paper Width) sensor attached to the left edge guide in ASF
CR PW sensor attached to the right side of the CR unit.
PL (Paper Length) sensor attached to the lower housing.
This must be performed whenever the main control board or the CR unit is replaced. Follow the step 1 to 4 to enter the Sensor check menu.
1.Connect the printer and the host computer with a parallel interface cable.
2.Start the adjustment program in the host computer.
3.Input the market code. (Refer to Section 4.1.2.)
4.Move the cursor using − or ↓ key to select “3. Sensor Check” from the Main menu. Then press “Return” key, and the Sensor Check menu appears.
< 3. Sensor Check >
1.
2.ASF Quantity
3.
4.ASF Length
5.PG
R. Rerturn
CAUTION
Don not set any paper or tool unless instructed.
If any sensor does not function properly, all LED indicators blink. In that case, check the connection of the sensors and the main control board.
Rev. A |