Troubleshooting
TableCondition | Cause | Checkpoint | Solution |
|
|
|
|
CR motor does not rotate Sub gate array IC16 | Check the waveform for the | Replace the MAIN | |
normally. | is defective. | signals HPASEA/B (Pin 7) output | board or IC16. |
|
| from the IC19/20. |
|
HPASE on the IC20 (Pin 7)
OUTA on the IC19 (Pin 10)
| Waveform (9) |
| |
CPU is defective. | ⎯ | Replace the MAIN | |
board. | |||
|
| ||
IC19 or IC20 is | Check the the drive waveform Replace the IC19 or | ||
defective. | for the signals !"# (Pin 10/15) | IC20. | |
| output from the IC19/20. |
| |
| (See the waveform (9)) |
| |
|
|
| |
CR motor is | Check if the resistance of the | Replace the CR motor. | |
defective. | motor coil is as follows; |
| |
| 5Ω ± 7 % at 25°C per phase |
| |
| (Refer to Table |
|
PF motor does not | Sub gate array IC6 | Check the waveform for one of | Replace the MAIN |
operate normally. | is defective. | the following signals output from | board. |
|
| the IC17: |
|
|
| PFA0/1 (Pin1/2) |
|
|
| PFB0/1 (Pin 23/24) |
|
Pin 1 on the IC17
Pin 6 on the IC 17
|
| Waveform (10) |
|
|
| CPU is defective. | ⎯ | Replace the MAIN |
|
| board. |
| ||
|
|
|
| |
|
|
|
| |
| IC17 is defective. | Check the wavefoarms for one of Replace the MAIN |
| |
|
| the following signals output from | board. |
|
|
| the IC17: |
|
|
|
| PFA0/1 (Pin 2/1) |
|
|
|
| PFB0/1 (Pin 23/24) |
|
|
|
| (Refer to the waveform (10).) |
|
|
|
|
|
|
|
| PF motor is | Check if the resistance of the | Replace the PF motor. |
|
| defective. | motor coil is as follows; |
|
|
|
| 10Ω ± 10 % at 25 °C |
|
|
|
| (Refer to Table |
|
|
|
|
|
|
|
|
|
|
|
|
Rev. A |