4.Remove 1 screw (CBS, 3X6) under the panel unit and 7 screws (CBP, 3X12) securing the upper housing to the lower housing.
5.Inserting tweezers from the bottom side of the lower housing, release 2 hooks fixing the upper housing to the lower housing. Then remove the upper housing by pulling it forward.
WORK POINTWhen replacing the upper housing or printer cover, be sure to remove the label such as CAUTION and put it to the same position on the replaced part.
Gap Adjust Lever |
|
|
CBP Screw (3x12) | CBP Screws (3X12) | Tractor Unit |
|
| |
|
| Sheet Guide |
Knob |
|
|
CBS Screw (3X6)
Panel Unit
Hook
Upper Housing
Tweezers | Lower Housing |
|
Hook
FigureRev. A |