4.1.9.1 PQ Sensor AdjustmentCAUTION
Follow the steps exactly in the way instructed. Otherwise the fatal error will occur.
Inaccuracy in this adjustment does not guarantee the proper operation of the printer.
1.Enter the “Sensor Check” menu. (See Section 4.1.9.)
2.Move the cursor using − or ↓ key to select
3.Move the cursor using − or ↓ key to select “2. ASF Quantity” . and press “Return” key.
4.Remove paper and press “Return” key.
5.Set a stack of paper * or the paper quantity detective adjust tool on the right edge guide in the ASF. Then press “Return” key, and the Sensor check menu appears.
PQ Sensor Lever
Paper Quantity Adjusting Tool
9 mm
| Right Edge Guide |
Figure | |
Note) Stack of paper: | With a thickness of 9 mm to 9.1 mm or approximately 100 sheets of |
|
Rev. A |