Product Descriptions

1.3.10 Electric Specifications120 V version

￿ Rated voltage

AC 120 V

￿ Input voltage range

AC 103.5 to 132 V

￿ Rated frequency renege

50 to 60 Hz

￿ Input frequency range

49.5 to 60.5 Hz

￿ Rated current

0.7 A (maximum)

￿ Power consumption

Approximately 21 W (ISO/IEC 10561 Letter pattern)

 

Energy Star program compliant

￿ Insulation resistance

10 M ohms min. (Between AC line and chassis, 500 VDC)

￿ Dielectric strength

AC 1,000 V rms. For 1 minute or

 

AC 1,200 V rms. For 1 second (Between AC line and chassis)

220 - 240V version

￿ Rated voltage

AC 220 to 240 V

￿ Input voltage range

AC 198 to 264 V

￿ Rated frequency renege

50 to 60 Hz

￿ Input frequency range

49.5 to 60.5 Hz

￿ Rated current

0.4 A (maximum)

￿ Power consumption

Approximately 21 W (ISO/IEC 10561 Letter pattern)

 

Energy Star program compliant

￿ Insulation resistance

10 M ohms min. (Between AC line and chassis, DC 500 V)

￿ Dielectric strength

AC 1,500 Vrms. For 1 minute (Between AC line and chassis)

1.3.11 Environmental Conditions
￿ Temperature

 

￿ Operating*1

10°C to 35°C

￿ Non operating*2

-20°C to 60°C

 

1 month at 40 °C (104 °F)

 

120 hours at 60 °C (140 °F)

￿Humidity

￿

Operating*1

20% to 80% RH (without condensation)

￿

Non operating*2

5% to 85% RH (without condensation)

￿Resistance to vibration

￿

Operating

0.15 G

￿

Non-operating*2

0.50 G

￿Resistance to shock

￿

Operating

1 G within 1 ms

￿

Non-operating*2

2 G within 2 ms

*1 :Refer to the table below for guaranteed range.

*2 :In shipment container.

90

80

70

60

Humidity (%) 50

Operating Environment

40

30

20

.

27 35

10 20 30 40 Temperature (C)

Figure 1-7. Environmental Conditions

1-14

Rev. A