Disassembly and Assembly

3.2.10 PL (Paper Length) Sensor Removal

1.Remove the upper housing. (See section 3.2.1.)

2.Remove the printer mechanism unit. (See Section 3.2.6.)

3.Disconnect the connector cable for the PL sensor from the CN11 on the main board assembly.

4.Using tweezers, release 3 hooks securing the PL sensors to the lower housing.

WORK POINT

Make sure you connect each connector cable to the appropriate connector paying attention to the cable length which locates the proper connector.

Connector Switches

Lower Housing

Figure 3-12. PL Sensor Removal

3-16