Digital halftoning
4 dither patterns (A, B, C, and D) for
(2 downloadable dither patterns)
Gamma correction
2 types for CRT display
3 types for printer
1 type
Color correction
1 type for CRT display
3 types for printer (available in color byte sequence mode and color line sequence mode)
1 type
Interfaces
SCSI (micro DB
Optional IEEE 1394 I/F slot
Light source
Xenon gas cold cathode fluorescent lamp
Reliability
600,000 cycles of carriage movement (main unit MCBF)
Dimensions |
|
Width: | 25.9 inches (658 mm) |
Depth: | 19.2 inches (488 mm) |
Height: | 10 inches (254 mm) |
Weight |
|
Approximately 66 lb (37.5 kg)
Electrical
Input voltage range
100 to 120 VAC: 90 to 132 VAC
220 to 240 VAC: 198 to 264 VAC
Rated frequency
50 to 60 Hz
Rated current
100 to 120 VAC: 0.8 A
220 to 240 VAC: 0.4 A
Power consumption
Operating: Approximately 60 W Approximately 65 W with ADF unit
Standby: Approximately 12 W
Environmental
Temperature
Operating: 41 to 95 °F (5 to 35 °C) 50 to 89 °F (10 to 32 °C) when using ADF
Storage: − 13 to 140 °F (− 25 to 60 °C)
Humidity (without condensation)
Operating: 10 to 80%
Standby: 10 to 85%
Operating conditions
Ordinary office or home conditions. Avoid dust, direct sunlight, and proximity to strong light sources.
Safety Approvals
120 V model
Safety: UL 1950 CSA C22.2 No. 950
EMC FCC part 15 subpart B class B CSA C108.8 class B
230 V model |
|
Safety: | EN 60950 |
EMC: | EN 550022 |
| (CISPR Pub 22) class B |
| AS/NZS 3548 class B |
130 Specifications