SCSI Interface
Interface type
SCSI 2 and SCSI 3
Logic level
ID setting
Selectable from 0 to 7
Terminator
Internal terminator (enable/disable selectable)
Connector select switch
W:
N:
Connector type
Micro DB
Initialization methods
Hardware: Initialized when the scanner is turned on or the scanner receives a SCSI Reset signal from the SCSI interface
Software: Initialized when the software sends the Esc @ (initialize the scanner command), or the scanner receives a SCSI Bus Device message
IEEE 1394 Scanner Interface
Interface type
IEEE 1394 compatible
Data transfer method
Synchronization method
Clock synchronization with
Encoding/decoding
Logic level
3.3 V
Compatible connectors
IEEE
Power class
Power class code 100
No power supply from external sources Fitted with a repeat function with bus power
Environmental
Temperature
Operating: 41 to 95 °F (5 to 35 °C)
Standby: − 13 to 140 °F (− 25 to 60 °C)
Humidity (without condensation)
Operating: 10 to 80%
Standby: 10 to 85%
Option Interface Connector
Interface type
For use with the automatic document feeder (B813212)
Output voltage
21.6to 26.4 VDC
4.75to 5.25 VDC
Output current
0.6A (24 V)
0.3A (5 V)
Specifications 131