Epson SEIJ98006 Isolating the Faulty Part on the Power Supply Board, EPSON Stylus Color, Overview

Models: SEIJ98006

1 200
Download 200 pages 59.25 Kb
Page 90
Image 90
3.1.2 Isolating the Faulty Part on the Power Supply Board

EPSON Stylus Color 900

Revision C

3.1.2 Isolating the Faulty Part on the Power Supply Board

This section explains how to troubleshoot the following problems:

The printer is turned on, but the initialization is not performed and

￿LED on the control panel do not come on. Problems after power on

Be sure to perform troubleshooting in the order specified, because the parts involved are mentioned in the disassembly procedure to facilitate servicing.

Table 3-17. Isolating the Faulty Part on the Power Supply Board

Step

Check Point

Action

 

 

 

1

Is the panel FFC

The power switch for this printer is in the secondary

 

disconnected from the

side. Therefore, if the FFC does not transfer

 

connector on the panel

signals, the printer does not operate despite the

 

board?

power supply board and the main board are

 

 

properly connected.

 

 

 

2

Is the panel FFC

This printer uses the power switch on the

 

disconnected from the

secondary side. Therefore, if the FFC does not

 

connector (black, 12-

transfer signals, the printer does not operate

 

pin) on the relay board?

despite the power supply board and the main board

 

 

are properly connected.

 

 

 

3

Is the connector

The reason is the same as above.

 

disconnected from the

The panel control FFCs are connected via 1) CN15

 

CN15 on the main

on the main board 2) Relay board 3) Control

 

board?

Panel.

 

 

 

4

Has the fuse (F1) on

Check if the line in the F1 located beside the CN1

 

the power supply board

on the power supply board has blown.

 

blown?

 

 

 

 

5

Is CN2 or CN3 on the

Check that the connectors CN2 and CN3, which

 

power supply board

are used to apply power to the main board, are

 

disconnected?

properly connected.

 

 

 

Table 3-18.

Isolating the Faulty Part on the Power Supply Board (continued)

Step

Check Point

 

Action

 

 

 

 

 

6

Is CN 5 or CN6 on the

Check that the connectors CN5 and CN6, which

 

main board

are used to input power from the power supply

 

disconnected?

board, are properly connected.

 

 

 

 

 

7

Is the choke coil

Viewing the reverse side of the power supply

 

broken?

board, check for the proper continuity at the two

 

 

points indicated in the figure below.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L 1 ( r e v e r s e s

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C N 1

 

sCidN e2 s id e

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

Is the transformer (T1)

Referring to the figure below, check if the

 

broken?

transformer is disconnected between the poles. Try

 

 

every combination in each group marked with a

 

 

blue box.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T 1

( r e v e r s

C N 5 CSNid3

Troubleshooting