First Digit

Confidential

IP

TM-U230 Developer’s Guide

The ability of an enclosure to keep out dirt and water is defined in IEC 529. When an enclosure protects the equipment from water and particles of dirt, it also protects people from any potential hazard inside the equipment.

The degree of protection is designated by the letters "IP" followed by two digits such as "IP01" or "IP34." The first digit indicates the degree that the equipment is protected from solid foreign objects. The second digit indicates the degree that the equipment is protected from water. The details are described in the tables below. The first digit, protection from solid foreign objects, is divided into "protection from human contact" and "protection from foreign bodies."

First Digit

 

Protection From Human Contact

Protection From Foreign Bodies

 

 

 

 

 

0

 

No protection

No protection

 

 

 

 

 

1

 

Protection from the palm of a hand

Protection from foreign bodies with a

 

 

 

 

diameter greater than 50 mm

 

 

 

 

 

2

 

Protection from fingers

Protection from foreign bodies with a

 

 

 

 

diameter greater than 12.5 mm

 

 

 

 

 

3

 

Protectionfromtoolsandthinwires,etc.with

Protection from foreign bodies with a

 

 

a diameter more than 2.5 mm

diameter greater than 2.5 mm

 

 

 

 

 

4

 

Protectionfromtoolsandthinwires,etc.with

Foreign body with a diameter greater

 

 

a diameter more than 1 mm

than 1 mm

 

 

 

 

 

5

 

Complete protection

Protection from grainy foreign bodies

 

 

 

 

(only a certain amount is permitted)

 

 

 

 

 

6

 

Complete protection

Complete protection from grainy foreign

 

 

 

 

bodies

 

 

 

 

 

 

 

 

 

Second Digit

 

Ability to keep water out

 

 

 

 

 

 

0

 

 

No protection

 

 

 

 

 

1

 

 

Keeps out water coming from directly above

 

 

 

 

2

 

 

Keeps out water coming from an angle up to 15° from vertical

 

 

 

 

3

 

 

Keeps out water sprayed at an angle of 60° from vertical

 

 

 

 

4

 

 

Keeps out water sprayed from all directions (only a certain amount of water

 

 

 

penetrating the enclosure is permitted)(*)

 

 

 

 

 

5

 

 

Keeps out low pressure water jet sprayed from all directions (only a certain amount of

 

 

 

water penetrating the enclosure is permitted)(*)

 

 

 

 

6

 

 

Keeps out high pressure water jet sprayed from all directions (only a certain amount of

 

 

 

water penetrating the enclosure is permitted)(*)

 

 

 

 

7

 

 

Keeps out water during temporary immersion

 

 

 

 

8

 

 

Keeps out water during permanent immersion

 

 

 

 

 

(*) : Only a certain amount of water may enter though the printer can continue printing.