Confidential

TM-U230 Developer’s Guide

 

The usage of DirectIO in OPOS

This Chapter describes the programming samples of DirectIO in OPOS.

Executes a paper cut automatically when the current position reaches the autocutter position. Executes a paper cut after feeding for 4 + pData ∗ 0.176 [mm]. The value of the pData is 0 in the following example. (the available range of pData is 0 - 255)

This function is canceled when the FEED button is pressed or a command that results printer reset is executed.

Command: PTR_DI_DELAYED_CUT Execute the delayed cut

pData : Specify feed lines to the autocutter position

pString : Not used

Dim RC As Long

Dim pString As Long

Dim pData As String

pString = PTR_DI_DUMMY

pData = 0

.....Printing process.....

RC = Coptr1.DirectIO(PTR_DI_DELAYED_CUT ,pData,pString)

Programming Samples 4-7

Page 55
Image 55