Confidential

For the TM-U210 series printers, when DIP switch 1-2 is off, the following commands cannot be used; however the TM-U230 can use them.

Printer

Name

 

 

HT

Horizontal tab

 

 

ESC %

Select/cancel user-defined character set

 

 

ESC &

Define user-defined characters

 

 

ESC ?

Cancel user-defined characters

 

 

ESC D

Set horizontal tab positions

 

 

FS 2

Define user-defined Kanji characters (only for Multilingual specification)

 

 

FS ?

Cancel user-defined Kanji characters (only for Multilingual specification)

 

 

Receive buffer full conditions are different.

Printer

Receive buffer-full conditions

 

 

TM-U230

When the remaining memory size becomes 128 bytes, the printer will be BUSY

 

and when it returns to 256 bytes, the BUSY condition will be canceled.

 

 

TM-U210 series

When the remaining memory size becomes 16 bytes, the printer will be BUSY

 

and when it returns to 26 bytes, the BUSY condition will be canceled.

 

 

Mounted Mechanism

 

 

Printer

Mounted Mechanism

 

 

TM-U230

Autocutter and near-end sensor are standard equipment

 

Has no paper roll take-up device

 

 

TM-U210 series

Near-end sensor is an option

 

Available with or without an autocutter

 

Available with or without a paper roll take-up device

 

 

Page 254, 255 (Space Page)

There is difference in a memory mapping.

Printer

Memory Mapping

 

 

 

 

 

 

TM-U230

Page 254

7 9 font

First address ECBA0

 

 

 

 

 

 

9 9 font

First address ED5A0

 

 

 

 

 

Page 255

7 9 font

First address EE1A0

 

 

 

 

 

 

9 9 font

First address EEBA0

 

 

 

 

TM-U210 series

Page 254

7 9 font

First address 8CBA0

 

 

 

 

 

 

9 9 font

First address 8D5A0

 

 

 

 

 

Page 255

7 9 font

First address 8E1A0

 

 

 

 

 

 

9 9 font

First address 8EBA0

 

 

 

 

3-4Compatibility

Page 48
Image 48
Epson U230 manual Mounted Mechanism, 254, 255 Space