INSTALLATION

24-pin connector on one end, and a standard 24-pin connector on the other.

To install the data bus cables, connect the IAM unit (if present) first, then the Master GTI unit, and finally the standard GTI units (from the lowest channel to the highest channel). Plug the standard connector of the first cable directly into the first unit, and the stackable connector of the first cable directly into the second unit. Then plug the standard connector of the second cable into the stackable connector of the first cable (which is plugged into the second unit), and the stackable connector of the second cable directly into the third unit. Continue connecting the cables in this way until all units are connected together. Then, plug the PCM/Data bus termination plug into the stackable connector of the last cable (which is plugged into the last unit).

Figure 1 shows the standard routing for a typical ELI system. Figure 32 shows the pin-out information for PCM/Data bus cables.

Female Part of Connector Mates with Next Cable

 

 

Male Part of Connector Mates with GTI / IAM

1

1

1

 

 

PCM Data Bus - Bit 0

13

13

13

2

2

2

 

 

PCM Data Bus - Bit 1

14

14

14

3

3

3

 

 

PCM Data Bus - Bit 2

15

15

15

4

4

4

 

 

PCM Data Bus - Bit 3

16

16

16

5

5

5

 

 

PCM Data Bus - Bit 4

17

17

17

6

6

6

 

 

PCM Data Bus - Bit 5

18

18

18

7

7

7

 

 

PCM Data Bus - Bit 6

19

19

19

8

8

8

 

 

PCM Data Bus - Bit 7

20

20

20

9

9

9

 

 

PCM Data Bus - Frame Sync

21

21

21

10

10

10

 

 

Console Data Bus

22

22

22

11

11

11

 

 

Subscriber Data Bus

23

23

23

12

12

12

 

 

Repeater Data Bus

24

24

24

Figure 32 - PCM / Data Bus Cable

Site Controller Computer

Two data cables must connect the Master GTI to the Site Controller computer. Connect a 19B803826P1 cable from the left female RJ-11-6 connector on the back of the Master GTI, to Port 30 on the back of the Site Controller computer. Connect a 19B803826P2 cable from the right female RJ-11-6 connector on the back of the Master GTI, to Port 31 on the back of the Site Controller computer. The locations of Ports 30 and 31 on the back of the Site Controller computer are shown in Figure 33.

Port 31 (LIC)

Port 30 (RIC)

Figure 33 - Site Controller Computer Connections

11. IAM SOFTWARE

The 11th step to install the ELI option applies only if an IAM was supplied. Record the software version number marked on the software PROM in the IAM unit. If a problem is later encountered with the equipment, the software version number may be essential to help with the diagnosis.

The location of the software PROM in the IAM unit is shown in Figure 34.

U23

FRONT

Figure 34 - IAM Software Locations

The IAM software is stored in U23 in the IAM. A sample label for U23 is shown in Figure 35. The actual version number of the software supplied may be different than that shown.