2.6 Alarm input / output installation

The EDR920/1640 alarm inputs can be used for recording start or recording rate adjustment. Furthermore, alarm reactions such as camera switching to monitors, buzzer, e-mail and network alarm are available. An alarm output relay can be switched if required.

EDR920 provides 9 alarm inputs, EDR1640 provides 16. All inputs are programmable NO/NC. Inputs have to be switched through dry contacts.

The 4 output relays provide a dry NO/NC contact. All settings are programmed in the ALARM menu.

Use either the 37-pin Sub-D plug or the included adaptor board for connection.

Pin assignment Sub-D plug

 

 

DVR

 

PIN #

NAME

PIN #

NAME

1

GND

19

GND

2

ALM 1

20

ALM-NC0

3

ALM 2

21

ALM-NO0

4

ALM 3

22

ALM-COM0

5

ALM 4

23

ALM-NC1

6

ALM 5

24

ALM-NO1

7

ALM 6

25

ALM-COM1

8

ALM 7

26

ALM-NC2

9

ALM 8

27

ALM-NO2

10

ALM 9

28

ALM-COM2

11

ALM 10

29

ALM-NC3

12

ALM 11

30

ALM-NO3

13

ALM 12

31

ALM-COM3

14

ALM 13

32

ALMRSTO

15

ALM 14

33

REC

16

ALM 15

34

GIN1O

17

ALM 16

35

DISKFULL

18

GND

36

GO1

Descriptions:

ALMINxx: Alarm input xx (1~16)

GND: common ground for alarm inputs

ALM_COMx: output relay x , contact root

ALM_NOx: output relay x , NO contact

ALM_NCx: output relay x , NC contact

ALMRST: Alarm reset, control input for alarm reset, for dry NO contact towards GND

DISKFULL: OC output contact for signal „HDD full“, switches to GND

REC_IN: Control contact for recording start

SPARE_IN / OUT: reserved

Pin assignment adaptor board

HOST

PIN #

NAME

PIN #

NAME

1

GND

21

GND

2

ALMIN 1

22

ALM_NC1

3

ALMIN 2

23

ALM_NO1

4

ALMIN 3

24

ALM_COM1

5

ALMIN 4

25

ALM_NC2

6

ALMIN 5

26

ALM_NO2

7

GND

27

ALM_COM2

8

ALMIN 6

28

GND

9

ALMIN 7

29

ALM_NC3

10

ALMIN 8

30

ALM_NO3

11

ALMIN 9

31

ALM_COM3

12

ALMIN 10

32

ALM_NC4

13

GND

33

ALM_NO4

14

ALMIN 11

34

ALM_COM4

15

ALMIN 12

35

GND

16

ALMIN 13

36

ALMRST

17

ALMIN 14

37

REC_IN

18

ALMIN 15

38

SPARE_IN

19

ALMIN 16

39

DISK_FULL

20

GND

40

SPARE_OUT

NO contact alarm input connection:

NC contact alarm input connection:

Output relay in idle state:

23