EverFocus EDR-1640, EDR-920 manual FAN Failure, Network Alarm

Models: EDR-920 EDR-1640

1 83
Download 83 pages 41.13 Kb
Page 50
Image 50

3.11 WARNING MENU

The EDR provides warning functions allowing signalling upon operation failure. Define the alarm reactions in the WARNING menu.

3.11.1 FAN FAILURE

WARNING SETUP MENU

FAN FAULT HDD TEMP. NO HDD HDD FULL

BUZZERENABLE ALARM OUTPUT 1

ALARM DURATION PERMANENT NETWORK ALARM NO

EMAILNO

Both fans provide failure detection. Define the alarm reactions upon fan failure in this menu item:

(1)BUZZER: By selection “ENABLE”, the buzzer is activated upon fan failure.

(2)ALARM OUTPUT: Output relay activation.

1 – Output relay 1 (for EDR410/810, only one output relay is available) NONE – no relay reaction upon alarm.

(3)ALARM DURATION: PERMANENT - This value cannot be changed, alarm is automatically switched off after problem has been solved (fan replacement).

(4)NETWORK ALARM:

YES: Network alarm activated (for settings refer to NETWORK menu)

Network alarm reception requires optional PowerCon software.

NO: No network alarm transmission

(5) EMAIL:

YES: Alarm email transmission (for settings refer to NETWORK menu).

NO: No email alarm transmission.

49

Page 50
Image 50
EverFocus EDR-1640, EDR-920 manual FAN Failure, Network Alarm