(5)REC QUALITY: Individual recording quality setting for this camera (within the resolution defined in RECORDING menu):

SUPERIOR

HIGH

STANDARD

BASIC

LOW

LOWER

Using the VBR (Variable Bit Rate) method, the storage requirement per image depends on the image’s colour and contrast content and captured motion. For recording time sample tables, please refer to Appendix D.

(6) REC SPEED ON TIME ZONE:

The EDR DVR offers 8 different timers for scheduled recording. The settings of the last row “N” (normal) apply to those periods not captured by a timer schedule (setup in TIMER menu)

For recording rate, the following steps are available: 1;2;3;4;5;6;8;10;12,5;25 images/s. In case no timer is activated, the DVR only operates according to the settings of row “N”.

TP: Timer program 1~8, schedule setup and activation are defined in the TIMER menu.

N:(Normal) all periods not captured by a timer schedule.

In case no timer is activated, the DVR only operates according to these settings.

NORMAL: IPS recording rate for manual or scheduled recording and recording controlled through “REC IN” input contact. The maximum image rate is limited to:

Max. image rate per camera = max. DVR recording rate / number of installed cameras. Max. DVR recording rate depends on recording resolution:

EDR920: 360x288: 200 image / second 720x288: 100 images / second

720x576: 50 images / second

EDR1640: 360x288: 400 images / second 720x288: 200 images / second

720x576: 100 images / second

Example: EDR1640 with 12 installed cameras, resolution 720x288:

200 IPS : 12 = 16,6 IPS > maximum adjustable recording rate per camera: 12,5 IPS

32

Page 33
Image 33
EverFocus EDR-920, EDR-1640 manual Superior High Standard Basic LOW Lower, REC Speed on Time Zone