3.11.2 HDD TEMP.
WARNING SETUP MENU
FAN FAULT HDD TEMP. NO HDD HDD FULL
BUZZER | ENABLE |
ALARM OUTPUT | 1 |
ALARM DURATION | PERMANENT |
NETWORK ALARM | NO |
NO | |
STOP RECORD | YES |
The enduring HDD temperature surveillance guarantees an alarm reaction in case the threshold value is exceeded.
There may be several reasons for HDD temperature excess:
-Exceedance of the max. tolerable ambient temperature (40°C), e.g. upon installation in an electrical cabinet with inadequate ventilation
-
-HDD defect
(1)BUZZER: By selecting “ENABLE”, the buzzer is activated upon HDD temperature excess.
(2)ALARM OUTPUT: Output relay activation.
1 – Output relay 1 ~ 4 (selection) switches upon alarm. NONE – no output relay reaction upon alarm.
(3)ALARM DURATION: PERMANENT - This value cannot be changed, alarm is automatically switched off after problem has been solved.
(4)NETWORK ALARM:
YES: Network alarm activated (for settings refer to NETWORK menu)
Network alarm reception requires optional PowerCon software.
NO: No network alarm transmission
(5) EMAIL:
YES: Alarm email transmission (for settings refer to NETWORK menu).
NO: No email alarm transmission.
(6) STOP RECORD
YES: Recording process is stopped to avoid further temperature rise and HDD damage.
NO: Recording process continues.
50