3.10 RS232/RS485 MENU

CONTROL SETUP MENU

RS232

 

 

BAUD RATE

9600 BPS

 

STOP BIT

1

 

PARITY

NONE

DATA BIT

8

 

RS485

 

 

BAUD RATE

9600 BPS

STOP BIT

1

 

PARITY

NONE

DATA BIT

8

 

RS232/RS485 ID

1

 

PTZ PROTOCOL

EVERFOCUS

Define the settings for DVR remote control through serial interface in the RS232/RS485 menu. Pin assignment and remote control protocol are described in appendix B and C.

(1)RS232 BAUD RATE: RS-232 interface transmission speed. 1200, 2400, 4800, 9600, 19200 and 3840 baud can be selected.

Default setting: 9600 baud

(2)RS232 STOP BIT: Number of stop bits: 1 or 2

(3)RS232 PARITY: Parity mode: NONE / EVEN / ODD

(4)RS232 DATA BIT: Number of data bits: 8 or 7

(5)RS485 BAUD RATE: RS-485 interface transmission speed. 1200, 2400, 4800, 9600, 19200 and 3840 baud can be selected.

Default setting: 9600 baud

(6)RS485 STOP BIT: Number of stop bits: 1 or 2

(7)RS485 PARITY: Parity mode: NONE / EVEN / ODD

(8)RS485 DATA BIT: Number of data bits: 8 or 7

(9)RS232/RS485 ID: RS232/RS485 address. Addressable range: 1~255.

This address complies with the device number for remote control through keyboards EKB 500, KS KBK and KS KBJ (DEVICE No.).

(10)PTZ-PROTOCOL:Protocol type setting for network telemetry control, available protocols:

EVERFOCUS1 (EPTZ1800 Dome), EVERFOCUS2 (EPTZ1000/3000 Dome),

ED2200/2250 (complies with Samsung protocol SCC-641/643), Pelco-D, Pelco-P

NOTE: Standard setting for EKB500 keyboard connection:

RS-485 Baud Rate: 9600, 1 stop bit, Parity NONE, RS232/RS485 ID = Device/DVR Nr. at keyboard

48

Page 49
Image 49
EverFocus EDR-920, EDR-1640 manual 10 RS232/RS485 Menu