3.2 CAMERA MENU

CAMERA

CAMERA1

TITLE

 

 

CH1

 

CAMERA2

PTZ ID

 

 

01

 

CAMERA3

INSTALL/COVERT

ON/OFF

CAMERA4

SEQ (MAIN/CALL)

03/03 SECS

CAMERA5

REC QUALITY

 

HIGH

CAMERA6

REC SPEED ON TIME ZONE

CAMERA7

TP

NORMAL

EVENT

SET

CAMERA8

1

5

IPS

25

IPS

OFF

CAMERA9

2

5

IPS

25

IPS

OFF

 

SUMMARY

3

5

IPS

25

IPS

OFF

4

5

IPS

25

IPS

OFF

 

5

5

IPS

25

IPS

OFF

 

6

5

IPS

25

IPS

OFF

 

7

5

IPS

25

IPS

OFF

 

8

5

IPS

25

IPS

OFF

 

N

5

IPS

25 IPS

OFF

Menu display for EDR-920, EDR1640 identical, but with 16 cameras.

The most important recording operation settings are defined in the CAMERA menu. Before changing the settings in this menu, recording has to be stopped.

Each camera is set individually:

(1)NAME: Enter the video channel description with max. 12 characters each. Available characters are (select with JOG):

0,1,2,3,4,5,6,7,8,9,

A,B,C,D,E,F,G,H,I,J,K,L,M,N,O,P,Q,R,S,T,U,V,W,X,Y,Z, ( ) . , + - / and space

(2)PTZ ID: Enter the RS-485 receiver address of a speed dome or telemetry receiver camera connected to this video channel.

(3)INSTALL / COVERT:

INSTALL (first position) All connected cameras have to be set to ON, all not connected cameras are set to OFF.

ATTENTION: The manual setting is compulsory, autodetection for connected cameras is not available!

COVERT (second position): A camera programmed COVERT “ON” will not be displayed, but recorded at defined parameters.

(4)SEQ(MAIN/CALL): Camera dwell time in sequence operation (automatic switching) for main (first position) and call (second position) monitor

ATTENTION: Some Pelco-D / -P protocol domes and receivers require an address offset of -1, i.e. the address assigned to the dome / receiver in the DVR camera menu must be 1 below the address set in the dome / receiver itself!

31

Page 32
Image 32
EverFocus EDR-1640, EDR-920 manual Camera Menu, Install / Covert