Example 6: Saving a preset

Operation, cont’d

Example 6: Saving a preset

See figure 3-12 and the following steps for an example of saving the current configuration as a preset on a 12x8 Matrix 50 switcher with audio.

1

 

 

 

 

 

 

 

 

 

 

 

F

 

 

 

LED key:

 

= off,

 

B

= blinking,

Press

 

 

 

 

 

 

F = flash once

 

 

 

C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INPUTS

 

 

 

 

 

1

2

3

4

5

6

7

8

9

10

11

12

1

2

3

4

5

6

7

8

 

 

 

 

 

 

 

OUTPUTS

 

 

 

 

 

 

 

C

Hold B

F Press

B

 

A

PRESET

ESC

 

CONTROL

 

I/O

ENTER PRESET VIEW

ESC

VIDEO AUDIO

Figure 3-12 — Example 6: Saving the current configuration as preset 1

APress and release the Esc button. The Esc LED flashes once.

BPress and hold the Preset button for approximately 2 seconds until the Preset LED begins to blink, then release the Preset button.

CPress and release the input 1 button. The input 1 LED lights flashes once. The Preset LED turns off.

Example 7: Recalling a preset

See figure 3-13 and the following steps for an example of recalling the current configuration as a preset on a 12x8 Matrix 50 switcher with audio.

F

 

 

 

LED key:

 

= off,

 

= on

 

Press

 

 

 

 

 

 

= flash once

 

 

 

 

C

 

 

 

F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INPUTS

 

 

 

 

 

1

2

3

4

5

6

7

8

9

10

11

12

1

2

3

4

5

6

7

8

 

 

 

 

 

 

 

OUTPUTS

 

 

 

 

 

 

 

C

Press

F

Press

 

B

 

A

PRESET

ESC

 

CONTROL

 

I/O

ENTER PRESET VIEW

ESC

VIDEO AUDIO

Figure 3-13 — Example 7: Recalling preset 1

APress and release the Esc button. The Esc LED flashes once.

BPress and release the Preset button. The Preset LED lights.

CPress and release the input 1 button. The input 1 LED flashes once. The Preset LED turns off. The configuration stored in memory location 1 is now the current configuration and can be viewed in the view-only mode (Example 4).