XTP T UWP 202 Wallplate Transmitter • XTP System Configuration Software 35

Import EDID

1. On the EDID Minder screen, click the Add EDID to Library button (see figure 31, 8).
The Browse window opens.
2. Select the desired EDID file and click Open. The EDID appears in the Available EDID
panel (see figure 31, 4).
3. Assign the EDID from the Available EDID panel to import the EDID setting to the device.

Save output EDID

1. On the EDID Minder screen, right-click on the desired EDID setting in the Connected
Outputs panel (see figure 31, 3).
2. Select the Save EDID to PC option. The EDID setting is saved to the connected PC.
Alternatively, right-click on the desired EDID, select Copy, and then Paste the EDID into
the Favorites or Available EDID panel.

Set favorite EDID

Commonly used EDID settings can be added to the Favorites panel for quick access.
1. Click and drag the desired EDID from the Connected Outputs or the Available EDID
panel to the Favorites panel. The EDID setting is copied to the Favorites panel (see
figure 31, 2). Alternatively, right-click the desired EDID and select Copy. Then Paste the
EDID setting into the Favorites panel.

EDID filters

The filters can be used to easily locate a specific EDID setting. Selectable filters include:
1 Resolution
2 Refresh Rate
3 Video Format
4 Audio Format
Figure 32. EDID Minder Filters
To use a filter or combination of filters:
1. Select an EDID setting from one of the drop-down lists of the associated filter (see
figure 32, 1-4). The available EDID options that match the filter selection are displayed
in their respective panels.
2. Repeat step 1 to apply more filters.
To clear the currently applied filters:
1. Click the Clear button next to the filters (see figure 32, 5). All filters are reset.

Common timings

This function automatically displays available EDID settings that are common among multiple
selected outputs.
1. Hold <Ctrl> and click the desired outputs in the Connected Outputs panel. The Common
Timings tab appears, listing the EDID settings common among the selected outputs.
2. Select the desired common EDID setting. The EDID will be shown in the Available EDID
panel.