XTP T UWP 202 Wallplate Transmitter • Installation and Operation 15
Remote power
The XTP T UWP 202 can be powered remotely through an XTP Power Injector or through
an XTP matrix switcher.
ATTENTION: XTP remote power is intended for indoor use only. No part of the network
that uses XTP remote power should be routed outdoors.
Power injector
To power the XTP T UWP 202 remotely with an XTP Power Injector, power one device
locally (see Local power on page 14) and connect an XTP Power Injector to the XTP
cable run along the XTP ports (see the XTP Power Injector User Guide for more installation
information).
Tx
RS-232
XTP T UWP 202
RS-232IR
Rx TxRxGTxRxG
12V
1.0 A MAX.
POWER
OVER XTP
XTP OUT
REMOTE
LAN
SIG LINK
XTP IN
POWER
12V
HDMI
1A MAX
RxGTx
RS-232 IR
RxTx +−+
LR 12
OVER XTP
AUDIO
OFF
ON
S/PDIF
RESET
XTP R HDMI
RELAYS
OUTPUTS
AUDIO
XTP
PWR
XTP PWR
100-240V50/60 Hz
---A MAX
Power
Extron
XTP R HDMI
XTP Receiver
Extron
XTP PI 100
XTP Power
Injector
Shielded Twisted Pair
Cable
Remote
Power
12V Local Power
Supply
Extron
XTP T UWP 202
XTP Transmitter
Figure 14. Typical Pont-to-point Application with Remote Power
NOTE: The power injector provides remote power up to 330 feet with a shielded twisted
pair cable with 24 AWG wire.
Direct power from an XTP matrix switcher
XTP matrix switchers have a fixed amount of power available to provide remote power
to connected XTP devices (see the XTP matrix switcher user guide for more details). To
manage available power from the XTP matrix switcher, use the XTP System Configuration
Software with the XTP matrix switcher.