XTP T UWP 202 Wallplate Transmitter • Installation and Operation 7
Installing a UL Listed Metal Junction Box
Metal junction boxes may differ slightly from model to model. Check with the manufacturer
for specific installation instructions.
ATTENTION: Use metal junction boxes only.
Signal Output
Cable
Cable
Clam
p
Screws or
Nails
Wall opening is
flush with edge
of box.
Wall Stud
Figure 4. Installing a Metal Junction Box
1. Insert the metal junction box into the hole in the wall.
2. Secure it to the stud using two screws or nails, as appropriate. The front edge of the
metal junction box must be flush with the front surface of the wall.
3. Feed cables through a metal junction box knockout opening.
4. Secure cables with clamps or ties to provide strain relief.
5. Trim back and insulate shields with heat shrink.
ATTENTION: To prevent short circuits, the outer foil shield can be cut back to the
point where the cable exits the cable clamp. Both braided and foil shields should
be connected to an equipment ground at the other end of the cable.

Rear and Side Panel Connectors

Tx
RS-232
XTP T UWP 202
RS-232IR
Rx TxRxGTxRxG
12V
1.0 A MAX.
POWER
OVER XTP
XTP OUT
REMOTE
BCD
Rear
Side
AA
A XTP output connector
B RS-232 and IR Over XTP connector
C Remote RS-232 connector
D DC power connector
Figure 5. Rear Panel Connectors