| Earth/Ground Tester |
| |
|
|
|
|
|
|
| Specifications |
| |
|
|
|
|
|
|
| |||
Resistance Measurement (RF) |
|
|
| ||||||
Measuring method: | current- voltage measurement as per |
| |||||||
|
|
|
| possible |
|
|
|
| |
Open circuit voltage: | 20 V DC |
|
|
|
| ||||
Short circuit current: | 200 mA DC |
|
|
| |||||
Formation of measured | with |
| |||||||
value: |
| be extended without additional error. |
|
| |||||
|
|
|
| Resistances >1 Ω in wire E can cause additional |
| ||||
|
|
|
| error of 5m Ω/Ω. |
|
|
| ||
|
|
|
|
|
|
|
|
| |
| Measuring |
| Display Range |
| Resolution | Intrinsic | Operating |
| |
| Range |
|
|
|
|
| Error | Error |
|
|
|
|
|
|
|
|
|
| |
|
|
| 0.001 Ω ... 2.999 Ω |
| 0.001 Ω |
|
|
| |
|
|
|
|
|
|
|
|
| |
| 0.020 Ω |
| 3.0 Ω ... 29.99 Ω |
| 0.01 Ω | ±( 2 % of | ±( 5% of |
| |
|
|
|
|
|
|
| m.v. +2 | m.v. +5 |
|
| 3 kΩ |
| 30.0 Ω ... 299.9 Ω |
| 0.1 Ω |
| |||
|
|
| digit) | digit) |
| ||||
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
| 300 Ω ... | 2999 Ω |
| 1 Ω |
|
|
|
|
|
|
|
|
|
|
| ||
Measuring sequence: | approx. 2 measurements/s |
|
| ||||||
Measuring time: |
| typ. 4 sec. incl. reversal of polarity (2 pole or 4 |
| ||||||
|
|
|
| pole) |
|
|
|
| |
Max. interference voltage: | ≤ 3 V AC or DC, with higher voltages measure- |
| |||||||
|
|
|
| ment will not be started |
|
|
| ||
Max inductivity: |
| 2 Henry |
|
|
|
| |||
Max. overload: |
| Urms = 250 V |
|
|
|
19