Fortinet 5001A-SW, 5001A-DW manual To change or verify the SW11 switch setting, Location of SW

Models: 5001A-SW 5001A-DW

1 40
Download 40 pages 49.38 Kb
Page 13
Image 13
To change or verify the SW11 switch setting

 

 

Hardware installation

Changing FortiGate-5001A SW11 switch settings

To change or verify the SW11 switch setting

To complete this procedure, you need:

A FortiGate-5001A board

A tool for changing the SW11 switch setting (optional)

An electrostatic discharge (ESD) preventive wrist strap with connection cord

Caution: FortiGate-5001A boards must be protected from static discharge and physical ! shock. Only handle or work with FortiGate-5001A boards at a static-free workstation.

Always wear a grounded electrostatic discharge (ESD) preventive wrist strap when handling FortiGate-5001A boards.

1 Attach the ESD wrist strap to your wrist and to an available ESD socket or wrist strap terminal.

2 If you have installed the FortiGate-5001A board in a chassis, remove it.

For removal instructions, see “Removing a FortiGate-5001A board” on page 18.

3 Use Figure 8 to locate SW11 on the FortiGate-5001A board.

The top of the FortiGate-5001A board is covered with a copper heat sink. The printed circuit board is under the copper heat sink. SW11 is located on the printed circuit board and is accessible from the left side of the FortiGate-5001A board under the copper heat sink (see Figure 8).

Figure 8: Location of SW11 on the FortiGate-5001A board

Location of SW 11

Factory Default (Shelf Manager Required)

 

ON

 

1

Off

SW11

 

 

 

 

 

2

On

 

 

 

 

 

3

Off

 

 

 

 

 

 

4

Off

 

1

2

3

4

 

 

 

Standalone Mode for FortiGate-5020 (no Shelf Manager)

 

ON

 

1

Off

SW11

 

 

 

 

 

2

On

 

 

 

 

 

3

On

 

 

 

 

 

4

Off

 

 

 

 

 

 

 

1

2

3

4

 

 

 

FortiGate-5001A boardLocation of SW 11(top view)

FortiGate-5001A Front Faceplate

4If required, change SW11 to the correct setting.

5Insert the FortiGate-5001A board into a chassis and verify that the board starts up and operates correctly.

For inserting instructions, see “Inserting a FortiGate-5001A board” on page 15.

Note: Figure 8 shows a FortiGate-5001A-DW board. The location of SW-11 is the same on a FortiGate-5001A-SW board.

FortiGate-5001A Security System Guide

 

01-30000-83456-20081023

13

Page 13
Image 13