GENERAL SPECIFICATIONS
|
|
SERIES | ENGINEERING CODE |
| OPTIONS |
DESIGN SERIES |
|
25 = | 2.5 KW |
34 = | 3.4 KW |
CHASSIS SPECIFICATIONS |
|
|
|
|
|
MODEL: |
|
|
|
|
|
23 | 1/8” | 23 | 1/8” | 23 | 1/8” |
23 | 1/8” | 23 | 1/8” | 23 | 1/8” |
32 | 1/4” | 32 | 1/4” | 32 | 1/4” |
26” X 28 | 1/2” X 35” | 26” X 28 | 1/2” X 35” | 26” X 28 | 1/2” X 35” |
|
| SEE CHARTS A & B (PAGE 11) |
|
| |
.3” WATER | .3” WATER | .3” WATER | |||
NOTES: |
|
|
|
|
|
ELECTRICAL DATA
|
| VEA09K |
|
| VEA12K |
|
| VEA18K |
|
|
|
|
|
|
|
| |||
HEATER WATTS | 2500/2050 | 3400/2780 | 5000/4090 | 2500/2050 | 3400/2780 | 5000/4090 | 2500/2050 | 3400/2780 | 5000/4090 |
VOLTAGE |
| 230/208 |
|
| 230/208 |
|
| 230/208 |
|
HEATING BTU/H | 8500/7000 | 11600/9500 | 17000/13900 | 8500/7000 | 11600/9500 | 17000/13900 | 8500/7000 | 11600/9500 | 17000/13900 |
HEATING CURRENT (AMPS) | 10.9/9.9 | 14.8/13.4 | 21.7/19.7 | 10.9/9.9 | 14.8/13.4 | 21.7/19.7 | 10.9/9.9 | 14.8/13.4 | 21.7/19.7 |
MINIMUM CIRCUIT AMPACITY | 15 | 19.9 | 28.6 | 15 | 19.9 | 28.6 | 15 | 19.9 | 28.6 |
BRANCH CIRCUIT FUSE (AMPS) | 15 | 20 | 30 | 15 | 20 | 30 | 15 | 20 | 30 |
LRA - COMPRESSOR (AMPS) | 22 | 22 | 22 | 30 | 30 | 30 | 42 | 42 | 42 |
COOLING CURRENT (AMPS) | 4.2/4.4 | 4.2/4.4 | 4.2/4.4 | 5.2/5.4 | 5.2/5.4 | 5.2/5.4 | 8.1/8.6 | 8.1/8.6 | 8.1/8.6 |
BASIC HEATER SIZE | 2.5 KW | 3.4 KW | 5.0 KW | 2.5 KW | 3.4 KW | 5.0 KW | 2.5 KW | 3.4 KW | 5.0 KW |
POWER CONNECTION |
| HARD WIRED |
|
| HARD WIRED |
|
| HARD WIRED |
|
|
|
|
|
|
|
|
|
|
|
RECOMMENDED BRANCH |
|
|
|
|
|
|
|
|
|
CIRCUIT WIRE SIZES | 14 | 12 | 10 | 14 | 12 | 10 | 14 | 12 | 10 |
* |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Important: ALL 208/230V CHASSIS MUST BE HARD WIRED WITH PROPERLY SIZED BREAKER. SEE NAMEPLATE FOR SPECIFIC CHASSIS ELECTRICA REQUIREMENTS. SEE FIGURE 15, PAGE 13 FOR UNIT WIRING AND WALL THERMOSTAT WIRING. SEE PAGE 12 FOR WIRE SIZE. USE HACR TYPE BREAKERS TO AVOID NUISANCE TRIPS. ALL FIELD WIRING MUST BE DONE IN ACCORDANCE WITH NEC AND LOCAL CODES.