CONNEXIONS DU THERMOSTAT À DISTANCE ET DES COMMANDES BASSE TENSION

THERMOSTAT À DISTANCE

TOUS LES APPAREILS VERT-I-PAK DE FRIEDRICH ONT ÉTÉ CONFIGURÉS POUR ÊTRE COMMANDÉS À DISTANCE PAR UN THERMOSTAT MURAL POUR UNE GESTION CHAUFFAGE/CLIMATISATION MONO-ÉTAGE. LA COMMANDE DE PERMUTATION PEUT ÊTRE AUTOMATIQUE OU MANUE- LLE DANS LA MESURE OÙ LA CONFIGURATION DES COMMANDES CORRES- POND À CELLE DU VERT-I-PAK.

POUR EFFECTUER LES CONNEXIONS DU THERMOSTAT :

1.COUPEZ L’ALIMENTATION ÉLECTRIQUE.

2.DÉVISSEZ ET RETIREZ LE COUVERCLE DU PANNEAU DE COMMANDES.

3.APRÈS AVOIR CHOISI UN CÔTÉ POUR L’ARRIVÉE LES FILS DU THERMOSTAT, AMENEZ LES FILS PAR L’OUVERTURE LATÉRALE DU BOÎTIER DE COMMANDES JUSQU’AUX BORNES DE BRANCHE- MENT.

4.EFFECTUEZ LES BRANCHEMENTS EN VOUS AIDANT DU SCHÉMA DE CÂBLAGE.

5.UNE FOIS LES BRANCHEMENTS CORRECTEMENT EFFECTUÉS, VOTRE APPAREIL EST PRÊT À FONCTIONNER.

6.REFERMEZ LE COUVERCLE DU PANNEAU DE COMMANDES.

CONNEXIONS POUR INTERRUPTEUR SECONDAIRE

LES VERT-I-PAK DE FRIEDRICH OFFRENT LA POSSIBILITÉ DE RACCORDER UN INTERRUPTEUR EXTERNE POUR COMMANDER L’ALIMENTATION ÉLECTRI- QUE DE L’APPAREIL. IL PEUT S’AGIR AUSSI BIEN D’UN SYSTÈME DE CONTRÔLE CENTRALISÉ QUE D’UN SIMPLE CONTACTEUR DE PORTE NORMALEMENT OUVERT.

POUR UTILISER CETTE OPTION, RACCORDEZ UN CÔTÉ DE L’INTERRUPTEUR À LA BORNE D1 ET L’AUTRE À LA BORNE D2 (VOIR FIGURE 15). LA FERME- TURE DE L’INTERRUPTEUR ENTRAÎNE L’ARRÊT DE L’APPAREIL.

NOTE : SYSTÈME DU TABLEAU DE COMMANDE ET INTERRUPTEURS NON COMPRIS.

LONGUEUR DE FIL MAXIMALE POUR INTERRUPTEUR SECONDAIRE

CALIBRE DE FIL

LONGUEUR MAXIMALE

 

 

#24

122 M

#22

183 M

#20

274 M

#18

457 M

#16

610 M

NOTE : IL EST DE LA RESPONSABILITÉ DE L’INSTALLATEUR DE S’ASSURER QUE TOUS LES BRANCHEMENTS DES COMMANDES SOIENT EFFECTUÉS CONFORMÉMENT AUX INSTRUCTIONS D’INSTALLATION. TOUT DÉFAUT DANS LE BRANCHEMENT DES COMMANDES DU THERMOSTAT ET TOUTE MODIFICATION DU CÂBLAGE INTERNE DU SYSTÈME DE CONDITIONNEMENT D’AIR ANNULERAIENT LA GARANTIE DE CE DERNIER ET POURRAIENT ENTRAÎNER DES DOMMAGES MATÉRIELS AINSI QUE DES BLESSURES POUVANT ÊTRE MORTELLES. SUR LES APPAREILS D’AUTRES MARQUES ET MÊME SUR LES ANCIENS MODÈLES DE FRIEDRICH, LE CÂBLAGE DES COMMANDES PEUT COMPORTER DES DIFFÉRENCES. POUR OBTENIR DES PRÉCISIONS SUR LE CÂBLAGE, S’ADRESSER DIRECTEMENT AU FABRICANT.

PANNEAU DE COMMANDES

FIGURE 14

Identification des connexions

Bome

Fonction

C

TERRE COMMUNE

GH

VENTILATEUR HAUTE VITESSE

GL

VENTILATUER BASSES VITESSE

BDEMANDE D'INVERSION A LA THERMOPOPE

Y

COMPRESSEUR

W

DEMANDE DE CHAUFFAGE

R

ALIMENTATION 24V ENTRE LE CONTROLEUR ET LE

THERMOSTAT MURAL

 

COMMANDE DE VENTILATEUR AUXILIAIRE

LE CONTRÔLEUR SMART CENTER A ÉGALEMENT LA CAPACITÉ DE COMMANDER UN RELAIS 24 V C.A. POUR ACTIVER UN VENTILATEUR AUXILIAIRE OU UN VENTILATEUR DE TRANSFERT. LES SORTIES SONT DÉSIGNÉES PAR F1 ET F2 SUR LE TABLEAU DE COMMANDES.

POUR CONNECTER LE RELAIS, RELIEZ SIMPLEMENT L’UN DES SES CÔTÉS

ÀLA BORNE F1 ET L’AUTRE À LA BORNE F2. À CHAQUE MISE EN MARCHE DU VENTILATEUR, LES BORNES TRANSMETTENT UN SIGNAL 24V C.A. AU RELAIS. LE RELAIS DOIT ÊTRE DE 24V C.A., 100 MA OU MOINS.

NOTE : RELAIS ET VENTILATEUR AUXILIAIRE DOIVENT ÊTRE FOURNIS SUR PLACE.