CARACTÉRISTIQUES GÉNÉRALES
GUIDE D´IDIDENTIFICATION DU MODÈLE VERT-I-PAK®
| NUMÉRO DE MODÈLE |
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
| SÉRIES |
|
|
|
|
|
| CODE DE FABRICATION | |
V: VERTICAL |
|
|
|
|
|
| OPTIONS | ||
E = CLIMATISATION AVEC CHAUFFAGE ÉLECTRIQUE |
|
|
|
|
| ||||
|
|
|
|
| RT : OCOMMANDE À DISTANCE STANDARD | ||||
H = THERMOPOMPE |
|
|
|
|
|
| |||
|
|
| PUISSANCE DU CHAUFFAGE ÉLECTRIQUE | ||||||
|
|
|
|
|
|
| |||
SPRÉSENTATION |
|
| |||||||
|
| SÉRIES A | |||||||
A = BOÎTIER DE 32’’/47’’ |
|
| 25 = | 2.5 KW | |||||
|
|
|
|
|
|
| 34 = | 3.4 KW | |
PUISSANCE NOMINALE |
| ||||||||
|
|
|
| ||||||
| SÉRIE A (BTU/H) |
|
|
|
| ||||
|
|
|
|
|
|
| SE REPORTER AU TABLEAU DES CARACTÉRISTIQUES | ||
| TENSION | ÉLECTRIQUES POUR LA COMPATIBILITÉ DU CHAUFFAGE ET | |||||||
|
|
|
|
|
|
| DE L’APPAREIL | ||
|
|
|
|
|
|
|
|
|
|
CARACTÉRISTIQUES DE L’APPAREIL
MODÈLE: |
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
TENSION (T) |
|
|
|
|
|
|
|
FRIGORIGÈNE |
| ||||||
LARGEUR DU CAISSON |
| 23 | 1/8" | 23 | 1/8" | 23 | 1/8" |
PROFONDEUR DU CAISSON |
| 23 | 1/8" | 23 | 1/8" | 23 | 1/8" |
HAUTEUR DU CAISSON ** |
| 32 | 1/4" | 32 | 1/4" | 32 | 1/4" |
DIMENS. À L’EXPÉDITION L X P X H |
| 26" X 28 | 1/2" X 35" | 26" X 28 | 1/2" X 35" | 26" X 28 | 1/2" X 35" |
COLLIER DE SORTIE D’AIR *** |
|
|
|
|
|
|
|
RACCORD DE DRAIN |
|
| FEM. |
| FEM. | FEM. | |
DÉBIT INTÉRIEUR (PI³/MIN) |
|
|
| VOIR TABLEAUX A ET B (PAGE 11) |
|
| |
PSE MAX. DES CONDUITS |
| .3” D’EAU | .3” EAU | .3” EAU |
Notes :
**LA HAUTEUR INCLUT LE COLLIER DE RACCORD DE CONDUIT DE 2’’ ET LES ISOLATEURS SOUS L’APPAREIL.
***LE COLLIER MONTÉ EN USINE CONVIENT AUX CONDUITS FLEXIBLES DE 10’’.
CARACTÉRISTIQUES ÉLECTRIQUES
|
| VEA09K |
|
| VEA12K |
|
| VEA18K |
|
WATTS CHAUFFE | 2500/2050 | 3400/2780 | 5000/4090 | 2500/2050 | 3400/2780 | 5000/4090 | 2500/2050 | 3400/2780 | 5000/4090 |
TENSION |
| 230/208 |
|
| 230/208 |
|
| 230/208 |
|
BTU/H CHAUFFAGE | 8500/7000 | 11600/9500 | 17000/13900 | 8500/7000 | 11600/9500 | 17000/13900 | 8500/7000 | 11600/9500 | 17000/13900 |
AMPÈRES CHAUFFAGE | 10.9/9.9 | 14.8/13.4 | 21.7/19.7 | 10.9/9.9 | 14.8/13.4 | 21.7/19.7 | 10.9/9.9 | 14.8/13.4 | 21.7/19.7 |
COURANT MIN. ADMISSIBLE | 15 | 19.9 | 28.6 | 15 | 19.9 | 28.6 | 15 | 19.9 | 28.6 |
DISJONCTEUR DIVIS. (A) | 15 | 20 | 30 | 15 | 20 | 30 | 15 | 20 | 30 |
COMPR. ROTOR BLOQUÉ (A) | 22 | 22 | 22 | 30 | 30 | 30 | 42 | 42 | 42 |
AMPÈRES CLIMATISATION | 4.2/4.4 | 4.2/4.4 | 4.2/4.4 | 5.2/5.4 | 5.2/5.4 | 5.2/5.4 | 8.1/8.6 | 8.1/8.6 | 8.1/8.6 |
PUISSANCE CHAUFFAGE STD | 2.5 KW | 3.4 KW | 5.0 KW | 2.5 KW | 3.4 KW | 5.0 KW | 2.5 KW | 3.4 KW | 5.0 KW |
CONNEXION AU SECTEUR | RACCORDEMENT FIXE |
| RACCORDEMENT FIXE |
| RACCORDEMENT FIXE |
| |||
|
|
|
|
|
|
|
|
|
|
RECOMMENDED BRANCH |
|
|
|
|
|
|
|
|
|
CIRCUIT WIRE SIZES | 14 | 12 | 10 | 14 | 12 | 10 | 14 | 12 | 10 |
* |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Important:TOUS LES APPAREILS DE 208/230V DOIVENT ÊTRE RACCORDÉS AU SECTEUR AVEC UN DISJONCTEUR DE PUISSANCE ADÉQUATE. LES CARACTÉRISTIQUES SPÉCIFIQUES DE L’APPAREIL SONT INDIQUÉES SUR LA PLAQUE SIGNALÉTIQUE DE L’APPAREIL. VOIR LE SCHÉMA DE BRANCHEMENT DE L’APPAREIL ET DU THERMOSTAT MURAL À LA FIGURE 15, PAGE 13. VOIR LES CALIBRES DES FILS
ÀLA PAGE 12. POUR ÉVITER LES DÉCLENCHEMENTS INTEMPESTIFS UTILISEZ DES DISJONCTEURS DE TYPE HACR. TOUS LES CÂBLAGES EFFECTUÉS SUR PLACE DOIVENT ÊTRE CONFORMES AUX EXIGENCES DU CODE CANADIEN DE L’ÉLECTRICITÉ ET AUX RÉGLEMENTATIONS LOCALES.
42